Description portable flow meter
It is ideal for flow surveys and closedpipe application where noninvasive measurement of Liquids is required.
Widely be used in water supply,heat supply,chemical industry,machinery and energy resources.
Specification portable flow meter
Items |
| Performance & Parameter |
Convertor | Principle | Transit- time ultrasonic flowmeter |
Accuracy | ±1% | |
Display | 2×20 character LCD with backlight, support the language of Chinese, English and Italy | |
Signal Output | 1 way 4-20mA output,electric resistance 0~1K,accuracy 0.1% | |
| 1 way OCT pulse output (Pulse width 6~1000ms,the default value is 200ms) | |
| 1 way relay output | |
Signal Input | 3 way 4-20mA input,accuracy 0.1%,acquire signals like: temperature,press and liquid level | |
| Achieve to heat maesurement by connecting the temperature transducer PT100 | |
Data Interface | Insulate RS485 serial interface,upgrade the flowmeter software by computer, support MODBUS | |
Data Record | Thermal printer,external SD card (2G of capacity) | |
Pipe Installation Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed |
Pipe Diameter | 15~ 6000mm | |
Straight Pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump | |
Measuring Medium | Type of Liquid | Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, etc. ) ;Plant effluent;Beverage;Ultra-pure liquids, etc. |
Temperature | -30~160°C | |
Turbidity | Less than 10000ppm and less bubble | |
Flowrate | 0~±10m/s | |
Working Environment | Temperature | Convertor:-20~60C; Flow Transducer:-30~ 160C |
Humidity | Convertor: 85%RH; Flow Transducer:IP67 | |
Power Supply | 8 built-in Ni-MH batteries 1.2V(for over 20 hours of operation).90V-260VAC adapter | |
Power Consumption | 1.5W |
Detail show portable flow meter
Clamp on sensor
Measuring way
More transducer for your choose
Types | Picture | Spec. | Model | Measurement Range | Temperature | Dimension |
Clamp on |
| Small Size | TS-2 | DN15~DN100 | -30~90°C | 45*25*32mm |
Medium Size | TM-1 | DN50~ DN700 | -30~90°C | 64*39*44mm | ||
Large Size | TL-1 | DN300~ DN6000 | -30~ 90℃ | 97*5453mm | ||
High temp. clamp on |
| Small Size | TS-2-HT | DN15~DN100 | -30~160℃ | 45*25*32mm |
Medium Size | TM-1-HT | DN50~ DN700 | -30~160℃ | 64*39*44mm | ||
Large Size | TL-1-HT | DN300~ DN6000 | -30~160℃ | 97*54*53mm | ||
(High temp.) Mounting bracket clamp on |
| Small Size | HS | DN15~ DN100 | -30~90℃ | 318*59*85mm |
HS-HT | DN15~ DN100 | -30~160℃ | 318*59*110mm | |||
| Medium Size | HM | DN50~ DN300 | -30~90℃ | 568*59*85mm | |
HM-HT | DN50~ DN300 | -30~160℃ | 568*59*110mm | |||
| Extended | EB-1 | DN300~DN700 | -30~90℃ | 188*59*49mm | |
EB-1-HT | DN300~ DN700 | -30~160℃ | 188*59*49mm |
Packaging portable flow meter
-
Download
GUF130 Handheld Ultrasonic flow meter
GUF130 Handheld Ultrasonic flow meter
Update time:2017.04.16