GWQ-EC300 conductivity meter is an intelligent one-line chemical analysis equipment, widely used in continuous monitoring of temperature and conductivity value of the solution in thermal power, chemical fertilizer, metallurgy, environmental protection, pharmaceutical, biochemical, food and running water and so on. The continuous monitoring data is realized by remote transmission monitoring and recording through the transmission output connection recorder. It can also be connected to the RS485 interface and can be easily connected to the computer for monitoring and recording through the MODBUS-RTU protocol.
1.Conductivity meter
2.RO water treatment
3.Multiple electrodes are available
Controller technical parameters:
Model | GWQ-EC300 |
Measuring range | 0.01~20uS/cm(with K=0.01 electrode) 0.1~200uS/cm(with K=0.1 electrode) 1.0~2000uS/cm(with K=1.0 electrode) 10~20000uS/cm(with K=10.0 electrode) 30~600mS/cm(with K=30.0 electrode) |
Accuracy | ±1%FS |
Resolution | 0.01uS/cm |
Repeatability | ±0.2%FS |
Temperature range | 0~100℃ |
Resolution (temperature) | 0.1℃ |
Accuracy (temperature) | ±0.5℃ |
Power supply | AC220V±20V,50Hz±1Hz |
Relay alarm | 220VAC/3A |
Communication | RS485 (compatible with MODBUS RTU) |
Transmitting function | 4-20mA output |
Dimensions (mm) | 146*146*150 |
Opening size(mm) | 138*138 |
cable length | Standard 5m ( cable length ≤25m) |
Electrode technical parameters:
Model | Electrode constant K | Measuring range | Material | Connection | Note |
GEC-EC0.01 | 0.01 | 0.01~20uS/cm | 316L, Titanium alloy | Hard pipe / hose /flange The pipe diameters are : Φ 6 , Φ 8 , Φ12 , etc. | Flow tight measurement |
GEC-EC0.1 | 0.1 | 0.1~200uS/cm | 316L,Titanium alloy | Hard pipe / hose /flange The pipe diameters are : Φ 6 , Φ 8 , Φ12 , etc. | 3/4 thread or flow cell |
GEC-EC1.0 | 1.0 | 1~2000uS/cm | 316L,Titanium alloy | 1/2,3/4 thread | 3/4 thread or flow cell |
GEC-EC10.0 | 10.0 | 10~20000uS/cm | 316L,Polysulfone | 3/4 thread | 3/4 thread or flow cell |
GEC-EC30.0 | 30.0 | 30~600mS/cm | 316L,Polysulfone | 3/4 thread | 3/4 thread or flow cell |
1. Multi-parameter display: simultaneously displaying the conductivity, output current, temperature, time and status.
2. Isolated transmission output, the interference is smaller .
3. Isolated RS485 communication .
4. Automatic temperature compensation function.
5. Watchdog program prevents the instrument from crashing.
6. Set the LCD backlight switch function .
7. Protection grade IP65
8. Measurement range is automatically converted .
Conductivity meter coupled to the electrode constant of 1.0 or 10.0 measurable general liquid; coupled with an electrode of 0.1 or 0.01, can accurately measure the conductivity of pure water or ultrapure water, especially suitable for steam power plants and boiler feed water On-line continuous monitoring of conductivity of high purity water such as condensate.
GWQ-EC |
|
|
|
| Note |
Model | 300 |
|
|
| CN or EN |
Electrode type | 0.01 |
|
| 0.01~20uS/cm | |
0.1 |
|
| 0.1~200uS/cm | ||
1.0 |
|
| 1.0~2000uS/cm | ||
10.0 |
|
| 10~20000uS/cm | ||
30.0 |
|
| 30~600mS/cm | ||
Electrode mounting | Z |
| Bracket ( standard ) | ||
L |
| Flow cell (0.01 electrode required ) | |||
K |
| Clamp ( only for 0.01 and 0.1electrodes ) | |||
Cable length
| W0 | 5m(standard) | |||
W1 | Customized(≤25m) |
For example:GWQ-EC3000.01ZW0
GWQ-EC300 conductivity meter,0.01 electrode,Electrode bracket mounting,cable 5m
Note:If you choose to install the electrode in the flow cell, you need to inform the inlet and outlet pipes that it is a hose or a hard pipe, and the diameter of the water pipe (φ6, φ8, φ12, etc.)