GTC703 Series economic digital temperature indicator is suitable for measurement, indicate, alarm and transmitter for temperature, humidity, pressure, flow, level and other physical parameters. The product had been widely applied to electricity, chemical industry, metallurgy, food processing, machinery manufacturing and other fields. The product is designed for a service life more than ten years and offers five years guarantee.
Product support programmable module input with this product effect of multi-channel
Could be reach to level of single channel.
Support two, four and six measurement channels
◆ Product support programmable module input, could be used for different inputs including various type of thermocouple, RTD, voltage, current and input of two-wire transmitters with 0.2 class accuracy. Channels could be set with different input format, graduation, position of base point, display resolution, digital filter strength, calibration correction and other settings.
◆ Since with high performance component, temperature drift was greatly decreased and there will be no interference between each channel. Hence with this product effect of multi-channel could be reach to level of single channel.
◆ GTC7032, 7043, 7036 support two, four and six measurement channels and were integrated with extraction, addition, subtraction and other calculation functions. The series is also with psychrometer calculation function compensated by wind velocity and atmospheric pressure constant, thus could measure temperature and humidity of the environment accurately with psychrometer and Pt100 input.
◆ Product support RS485 communication interface, could be used as terminal of AIDCS, remote data logger or touch screen control system, or provide input or output to PLC for operations with switch signal. In case communication function is not necessary, there could be two channels transmit output at top.
◆ It could allow 2 isolated transmitter current output at most. Users could sent measurement value out by OUTP port from any channel, or from the six channels in order. By similar process, product could be used as a transmitter with two input and two output ports.
◆ With set / auto data logging display function, and speed of data logging could be set.
◆ Product is compatible with the new E5 DIN rail and could be set through intelligent manipulator conveniently.
GTC- | Note | |||||||||||
Model | 7032 | Double channel alarm temperature indicator, 0.2 class accuracy with function of alarm, transmit, communication, etc. | ||||||||||
7034 | 1-4 channel display alarm temperature indicator, 0.2 class accuracy with function of alarm, transmit, communication, etc. | |||||||||||
7036 | 1-6 channel display alarm temperature indicator, 0.2 class accuracy with function of alarm, transmit, communication, etc. | |||||||||||
Dimension | A | Panel size 96×96mm, insert depth 100mm | ||||||||||
B | Panel size 160×80mm (width x height), insert depth 100mm | |||||||||||
C | Panel size 80×160mm (width x height), insert depth 100mm | |||||||||||
E | Panel size 48×96mm (width x height), insert depth 100mm | |||||||||||
E5 | Panel size 48×96mm (width x height), insert depth 100mm, din rail installation | |||||||||||
F | Panel size 96×48mm (width x height), insert depth 100mm | |||||||||||
Input channel 1 (M1) | J0 | One channel three-wire RTD input module (or one channel thermocouple + one channel two-wire RTD input) | ||||||||||
J1 | Two-channel thermocouple input module (support two-channel mV input) | |||||||||||
J2 | Two-channel two-wire RTD input module | |||||||||||
J3 | Two-channel voltage input module for 0~3V, 0~5V, 1~5V, etc. | |||||||||||
J4 | Two-channel current input module for 0~10mA, 4~20mA, 0~20mA | |||||||||||
J5 | Two-channel two-wire transmitter input module with 20V feed power | |||||||||||
Input channel 2 (M2) | J0 | One channel three-wire RTD input module (or one channel thermocouple + one channel two-wire RTD input) | ||||||||||
J1 | Two-channel thermocouple input module (support two-channel mV input) | |||||||||||
J2 | Two-channel two-wire RTD input module | |||||||||||
J3 | Two-channel voltage input module for 0~3V, 0~5V, 1~5V, etc. | |||||||||||
J4 | Two-channel current input module for 0~10mA, 4~20mA, 0~20mA | |||||||||||
J5 | Two-channel two-wire transmitter input module with 20V feed power | |||||||||||
Input channel 3 (M3) or Primary output (OUTP) | J0-J5 | Module function and selection of J0-J5 is same with “Input channel 1” | ||||||||||
L 0 | For domestic large size single channel relay output module (capacity 250VAC/2A) | |||||||||||
L2 | For small size single channel relay output module (capacity 250VAC/1A) | |||||||||||
L5 | Double channel relay output module (capacity 250VAC/2A) | |||||||||||
G | Solid state relay driving voltage output module (DC12V/30mA) | |||||||||||
X3/X5 | Photoelectric isolation linear current output module (X3 use power from the instrument, X5 with isolated power) | |||||||||||
Alarm (ALM) | L0-L5 | Please check item L0-L5 in “Input channel 3 (M3) or Primary output (OUTP)” | ||||||||||
Auxiliary alarm (AUX) | L0-L5 | Please check item L0-L5 in “Input channel 3 (M3) or Primary output (OUTP)” | ||||||||||
Communication (COMM) | S | Photoelectric isolation RS485 communication interface (use power from the instrument) | ||||||||||
S4 | Photoelectric isolation RS485 communication interface (with isolated power) | |||||||||||
X3/X5 | Photoelectric isolation linear current output module (X3 use power from the instrument, X5 with isolated power) | |||||||||||
Color | Q | Black | ||||||||||
Z | Gray |