GVF200 digital liquid vortex flow meter is a flow meter operating with Karman Vortex Street principle for flow rate of liquids (water, high temperature water, oil, beverage, chemical liquids, etc.). It could be used in automatic control system as flow transmitter. The product adopted advanced differential technique, together with measurement of isolating, shielding and filtering, it had possesses better anti-vibration performance and signal stability. GVF200 liquid flow meter is also with unique sensor encapsulation and protection technology to ensure service life of the sensor.
1.Good anti-vibration performance.
2.Low pressure loss and consumption
3.easy to install and maintain the product
Specifications:
1.Medium: water, high temperature water, oil, beverage, chemical liquids, etc.
2. Accuracy: Pipe type: Class 0.5 Insertion type: Class 2.5
3. Medium temperature: -40℃~+400℃
4. Nominal pressure: ≤1.6Mpa (offer ≤2.5Mpa and ≤4.0Mpa customization)
5. Flow rate: 0.6-6m/s
6. Output: Voltage pulse, 4-20mA output, HART, Modbus, RS485, RS232 options.
7. Installation: Flange, clamp flange, insertion, threat, clamp connection
8. Power: 220VAC±20% Voltage pulse output: +12VDC 4-20mA output: +24VDC battery
9. Operating condition: Temperature: -25℃~60℃ Humidity: 5%~90%
10. Housing material: 1Cr18Ni9Ti
Flow rate:
Clamp flange:
GVF200 |
|
|
|
|
|
|
|
|
|
| Note |
Nominal diameter | DNXX |
|
|
|
|
|
|
|
|
| DN15~DN1000 (mm) |
Structure | F |
|
|
|
|
|
|
|
| Remote type with display | |
Y |
|
|
|
|
|
|
|
| Compact type with display | ||
Accuracy | A |
|
|
|
|
|
|
| Pipe type: Class 1.0 | ||
B |
|
|
|
|
|
|
| Insertion type: Class 2.5 | |||
Nominal pressure | 16 |
|
|
|
|
|
| 1.6Mpa | |||
XX |
|
|
|
|
|
| Customization | ||||
Max. temp. of medium | M |
|
|
|
|
| <250℃ | ||||
H |
|
|
|
|
| >250℃ | |||||
Other function | P |
|
|
|
| With pressure compensation | |||||
T |
|
|
|
| With temperature compensation | ||||||
PT |
|
|
|
| With pressure and temperature compensation | ||||||
Power | 1 |
|
|
| 12~28VDC | ||||||
2 |
|
|
| 3.6V lithium battery (on site display) | |||||||
3 |
|
|
| 85~265VAC (Remote display) | |||||||
Output | A |
|
| 4-20mA | |||||||
M |
|
| Voltage pulse | ||||||||
H |
|
| HART | ||||||||
R1 |
|
| RS232 | ||||||||
R2 |
|
| RS485 | ||||||||
Installation | 1 |
| Flange | ||||||||
2 |
| Clamp flange | |||||||||
3 |
| Insertion | |||||||||
4 |
| Thread | |||||||||
5 |
| Clamp | |||||||||
Explosion proof | A | No explosion proof | |||||||||
B | Intrinsic explosion proof | ||||||||||
G | Flame proof |
Type selection process
Select main model and structure first, then ensure other specifications according to requirement, i.e. main model + nominal diameter + structure + accuracy + nominal pressure + Max. temperature of the medium + more function + power + output + installation + explosion proof.