It is ideal for flow surveys and closedpipe application where noninvasive measurement of Liquids is required.
Widely be used in water supply,heat supply,chemical industry,machinery and energy resources.
1.High Accuracy: 1%
2.Wide measuring range
3.Large capacity battery
4.Built-in printer
5.Data storage
6.RS485 communication interface
7.Various input and output signal
Items |
| Performance & Parameter |
Convertor | Principle | Transit- time ultrasonic flowmeter |
Accuracy | ±1% | |
Display | 2×20 character LCD with backlight, support the language of Chinese, English and Italy | |
Signal Output | 1 way 4-20mA output,electric resistance 0~1K,accuracy 0.1% | |
| 1 way OCT pulse output (Pulse width 6~1000ms,the default value is 200ms) | |
| 1 way relay output | |
Signal Input | 3 way 4-20mA input,accuracy 0.1%,acquire signals like: temperature,press and liquid level | |
| Achieve to heat maesurement by connecting the temperature transducer PT100 | |
Data Interface | Insulate RS485 serial interface,upgrade the flowmeter software by computer, support MODBUS | |
Data Record | Thermal printer,external SD card (2G of capacity) | |
Pipe Installation Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed |
Pipe Diameter | 15~ 6000mm | |
Straight Pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump | |
Measuring Medium | Type of Liquid | Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, etc. ) ;Plant effluent;Beverage;Ultra-pure liquids, etc. |
Temperature | -30~160°C | |
Turbidity | Less than 10000ppm and less bubble | |
Flowrate | 0~±10m/s | |
Working Environment | Temperature | Convertor:-20~60C; Flow Transducer:-30~ 160C |
Humidity | Convertor: 85%RH; Flow Transducer:IP67 | |
Power Supply | 8 built-in Ni-MH batteries 1.2V(for over 20 hours of operation).90V-260VAC adapter | |
Power Consumption | 1.5W |
Clamp on sensor
Measuring way
More transducer for your choose
Types | Picture | Spec. | Model | Measurement Range | Temperature | Dimension |
Clamp on | | Small Size | TS-2 | DN15~DN100 | -30~90°C | 45*25*32mm |
Medium Size | TM-1 | DN50~ DN700 | -30~90°C | 64*39*44mm | ||
Large Size | TL-1 | DN300~ DN6000 | -30~ 90℃ | 97*5453mm | ||
High temp. clamp on | | Small Size | TS-2-HT | DN15~DN100 | -30~160℃ | 45*25*32mm |
Medium Size | TM-1-HT | DN50~ DN700 | -30~160℃ | 64*39*44mm | ||
Large Size | TL-1-HT | DN300~ DN6000 | -30~160℃ | 97*54*53mm | ||
(High temp.) Mounting bracket clamp on | | Small Size | HS | DN15~ DN100 | -30~90℃ | 318*59*85mm |
HS-HT | DN15~ DN100 | -30~160℃ | 318*59*110mm | |||
| Medium Size | HM | DN50~ DN300 | -30~90℃ | 568*59*85mm | |
HM-HT | DN50~ DN300 | -30~160℃ | 568*59*110mm | |||
| Extended | EB-1 | DN300~DN700 | -30~90℃ | 188*59*49mm | |
EB-1-HT | DN300~ DN700 | -30~160℃ | 188*59*49mm |