Features
1. Double-U or double-C flow tube ensures high accuracy and customer’s requirement.
2. Provides integrated mass flow, volum flow, density, temperature measurement and relative calculated parameter.
3. Easy on Installation, do not need rectifier and filter parts.
4. Fixed parts, maintenace free. High stability, no need for frequent disassembly calibration.
5. Allow low-range operation, reducing pressure loss and energy consumption waste.
6. Integrated installation, low installation costs.
7. Extremely high accuray and long-term stability, could be used for business transaction.
8. Ultra-wide measure range, could measure gas accurately.
9. Transmitter can be exchanged, and will not be influenced by area temperature.
1.Accuracy in 0.2% or 0.15%
2.Double-U or double-C flow tube
3.Liquid,Gas,Air
Flange (HG/T20615-2009) | A | B | C | D | E | H | I | M | n | |
Flange (ASME B16.5) | ||||||||||
DN(mm) | PN(Class) | |||||||||
100(Option) | 300 | 932 | 824 | 1135 | 255 | 264 | 285 | 200 | 22 | 8 |
150(Option) | 300 | 956 | 824 | 1135 | 320 | 264 | 285 | 270 | 22 | 12 |
Mass Flow Accuracy | 15:1 within measure ratio ±0.1% |
15:1 beyond measure ratio ±(zero stability/instant flow rate) ×100% | |
Volume Flow Accuracy | Whole measure range ±0.15%±(zero stability/instant flow rate) ×100% |
Repeatability | 15:1 within measure ratio ±0.05% |
15:1 beyond measure ratio ±1/2(zero stability/instant flow rate) ×100% |
Dimension (DN100)
Note: Flanges in form are steel pipe flanges
Flange (GB/T9115.1-2000) | A | B | C | D | E | H | I | M | n | |
Flange (HG/T20592-2009) | ||||||||||
DN(mm) | PN(MPa) | |||||||||
100(standard) | 4.0 | 890 | 824 | 1135 | 235 | 264 | 285 | 190 | 22 | 8 |
100(Option) | 4.0 | 910 | 824 | 1135 | 300 | 264 | 285 | 250 | 26 | 8 |
Product series | GLM101 | Standard mass flow |
Sensor type | 10 | 0-1500kg/h |
15 | 0-4500kg/h | |
20 | 0-9450kg/h | |
25 | 0-25500kg/h | |
50 | 0-94500kg/h | |
80 | 0-240000kg/h | |
100 | 0-540000kg/h | |
150 | 0-825000kg/h | |
200 | 0-1650000kg/h | |
250 | 0-2700000kg/h | |
Transmitter type | W000 | None |
D100 | DPT100 [Accuracy 0.15, Chinese interface, IP65, Exde(ib)IICT6, Divided installation] | |
D101 | IPT200 [Accuracy 0.15, Chinese interface, IP65, Exde(ib)IICT6, Integrated installation] | |
I200 | IPT200 [Accuracy 0.2, Chinese interface, IP65, Exde(ib)IICT6, Divided installation] | |
I201 | IPT200 [Accuracy 0.2, Chinese interface, IP65, Exde(ib)IICT6, Integrated installation] | |
Sensor characteristics | B | 316L&304 Temperature-resistance 250℃ |
C | 316L Temperature-resistance 350℃ | |
R | 316L&304 Steam heat tracing type | |
D | 316L&304 Electric heat tracing | |
L | 316L | |
H | Hastelloy C22 | |
T | Customization | |
Power supply | 0 | None |
1 | 18VDC-36VDC | |
2 | 85VAC-265VAC | |
3 | Smart power | |
4 | Sensor 220VAC Transmitter 24VDC | |
Process connection type | A | GB/T9115.1-2000 4MPa RF |
C | GB/T9115.1-2000 6.3MPa RF | |
E | HG/T20615-2009 Class300 WN-RF | |
F | ASME B16.5-1988 Class150 WN-RF | |
G | ASME B16.5-1988 Class300 WN-RF | |
I | HG/T20592-2009 4MPa WN-RF | |
K | ASME B16.5-1988 Class600 WN-RF | |
T | Customization | |
Connection dimensions | B | DN15 |
D | DN25 | |
F | DN40 | |
G | DN50 | |
H | DN65 | |
I | DN80 | |
J | DN100 | |
L | DN150 | |
M | DN200 | |
N | DN250 | |
O | DN300 | |
T | Customization | |
Accessory | 0 | 10m cable |
1 | Carbon steel flange, bolt and nut, metal gasket, 10m cable | |
2 | Stainless steel flange, bolt and nut, metal gasket, 10m cable | |
3 | Carbon steel flange, bolt and nut, metal gasket | |
4 | Stainless steel flange, bolt and nut, metal gasket | |
5 | Customization | |
9 | None | |
Transmitter connection | W | M20 |
M | 1/2NPT | |
N | 3/4NPT | |
P | G1/2 | |
G | G3/4 | |
E | Customization | |
T | None | |
Communication | 0 | None |
1 | Active circulation (4-20mA), active frequency (0-10KHz), RS485 | |
2 | Active circulation (4-20mA), RS485 | |
3 | Active frequency (0-10KHz), RS485 | |
4 | Passive frequency(0-10KHz), RS485 | |
5 | Active circulation (4-20mA), active frequency (0-10KHz), passive HART (DPT transmitter only) | |
6 | Active circulation (4-20mA), active frequency (0-10KHz), active HART( DPT transmitter only) | |
7 | Passive frequency (0-10KHz), active HART (DPT transmitter only) | |
9 | Customization | |
Measurement mode | B | Standard measurement |
C | Water contents measuring | |
E | Density measuring | |
F | Viscosity measuring | |
G | Flow rate measuring | |
Z | Undefined |