1.High accuracy and thermal response fast
2.Various installation options meet customer requirements
3. K type armored thermocouple range:0-1000℃
4.Armored thermocouple range:(-200~+1300℃,could be made -270~+2800℃ for special conditions)
Thermocouple temperature sensors are widley applied to aviation, nuclear energy, petrochemical, metallurgy, machinery, electric power industries and technical area.
1. How could I choose a thermocouple?
With temperature range, chemical resistance requirement (or probe material), vibration and abrasion requirement and installation requirement, you may know which type of thermocouple do you need. You could also contact our sales for professional suggestions.
2. How will you ensure quality of your products?
A. All products had been treated through strict process according to ISO9001 standard and checked by IQC and OQC department before shipping.
B. One year warranty and life time free consult to any needs related with our product.
3. What terms of payment is acceptable?
T/T, L/C, trade assurance of Alibaba, Secure payment, West Union, Paypal, Money Gram, etc.
4. When production could be arranged?
As soon as the payment was received.
1.k s r b t type thermocouple
2.thermocouple temperature sensor
3.Wide temperature range
4.easy installation
Model and tolerance
Conductor | Model | Type | Admissible error class | ||
Class I | Class II | Class P | |||
Ni-Cr / Ni-Si | WRKK | K | ±1.5℃ or ±0.4%|t| | ±2.5℃ or ±0.75%|t| | / |
Ni-Cr-Si / Ni-Cr-Mg | WRKN | N | |||
Ni-Cr / Ni-Cu | WRKE | E | |||
Fe / Cu-Ni | WRKJ | J | |||
Cu / Cu-Ni | WRKT | T | ±0.5℃ or ±0.4%|t| | ±1.0℃ or ±0.75%|t| | / |
Pt-Rh10 / Pt | WRKS | S | / | / | ±3℃ or ±0.5%|t| |
Pt-Rh13 / Pt | WRKR | R | |||
Pt-Rh30 / Pt6 | WRKB | B | / | / | ±4℃ or ±0.5%|t| |
Thermocouple temperature sensor | |
Temperature range | 0- 400C |
Probe length | 7 inch |
Probe diameter | 3/8 inch |
Installation | thread 1/2-14NPS |
L:Total length Thread:G/NPT/BSP
Lo:insert length Junction box:waterproof / explosion proof / compact
d:probe diameter
(send us parameters or drawing reference)