GTC602 Series general usage digital temperature controller / regulator is an industrial temperature controller / regulator product specially made for general usage with artificial intelligence adjusting technology. The product is designed for a service life more than ten years and could meet requirement of different applications by providing various sub-models. GTC602 Series general usage digital temperature controller / regulator offers five years guarantee, easy maintenance and short delivery period. Besides, its performance of temperature drift and stability is better than similar instrument.
Product offers input options including thermocouple, RTD, voltage, current and other input options with integrated calibration form
Handy operation, easy to learn and master
Offer many control modes including standard PID, artificial intelligence (AI) adjusting APID, MPT, etc
Alarm will be switched off automatically while power up
Anti-interference performance
1. Product offers input options including thermocouple, RTD, voltage, current and other input options with integrated calibration form, separate correction is NOT necessary.
2. Product adopts advanced module structure and offers various output for different applications.
3. Handy operation, easy to learn and master.
4. Offer many control modes including standard PID, artificial intelligence (AI) adjusting APID, MPT, etc. Product with Auto tuning (AT) and adaptive learning function, no over or under shoot.
5. Alarm will be switched off automatically while power up.
6. Support RS485 and RS232, thus could be used as terminal of AIDCS, remote data logger or touch screen control system.
7. GTC602B had integrated program control function. By taking artificial intelligence (AI) adjusting algorithm, it could output smooth curve control.
8. Anti-interference performance of the product could meet requirement of electromagnetic compatibility (EMC) under harsh operating conditions.
Note | |||||||||
Model | 602A | Multiple output module options and two communication protocol options | |||||||
602B | With additional 30 segments on basis of GTC602 functions | ||||||||
Dimension | A | Panel size 96×96mm, insert depth 100mm | |||||||
A2 | Panel size 96×96mm, insert depth 100mm with bar indicator | ||||||||
B | Panel size 160×80mm (width x height), insert depth 100mm | ||||||||
B2 | Panel size 160×80mm (width x height), insert depth 100mm with bar indicator | ||||||||
C | Panel size 80×160mm (width x height), insert depth 100mm | ||||||||
C3 | Panel size 80×160mm (width x height), insert depth 100mm with bar indicator | ||||||||
D | Panel size 72×72mm, insert depth 95mm | ||||||||
D2 | Panel size 48×48mm, insert depth 95mm with 10 wiring terminals | ||||||||
D6 | Panel size 48×48mm, insert depth 95mm with 12 wiring terminals | ||||||||
E | Panel size 48×96mm (width x height), insert depth 100mm | ||||||||
E2 | Panel size 48×96mm (width x height), insert depth 100mm with bar indicator | ||||||||
E5 | Panel size 48×96mm (width x height), insert depth 100mm, din rail installation | ||||||||
F | Panel size 96×48mm (width x height), insert depth 100mm | ||||||||
Auxiliary input (MIO) | I2 | Switch signal input module, could be used for switch between two values for switch on and off control of instrument | |||||||
I4 | 0-20mA/4-20mA current input module, could provide 24V feed | ||||||||
V* | V24, V12, V10 modules are power modules for 24VDC, 12VDC, 10VDC | ||||||||
Primary output (OUTP) | L1 | For domestic large size single channel relay output module (capacity 250VAC/2A) | |||||||
L2 | For small size single channel relay output module (capacity 250VAC/1A) | ||||||||
L4 | For small size single channel relay output module (capacity 250VAC/2A) | ||||||||
G | Solid relay driving voltage output module (DC12V/30mA) | ||||||||
W1/W2 | Silicon controlled rectifier contactless switch output module (W1 for NO, W2 for NC) | ||||||||
X3/X5 | Photoelectric isolation linear current output module (X3 use power from the instrument, X5 with isolated power) | ||||||||
K1/K3 | Silicon controlled rectifier zero crossing triggering output module (K1 is with single channel, K3 will take MIO port and is with three-channel) | ||||||||
K5/K6 | Silicon controlled rectifier phase-shifted triggering output module (K5 is with 220V voltage, K6 is with 380V voltage) | ||||||||
Alarm (ALM) | L0 | For domestic large size single channel relay output module (capacity 250VAC/2A) | |||||||
L2 | For small size single channel relay output module (capacity 250VAC/1A) | ||||||||
L4 | For small size single channel relay output module (capacity 250VAC/2A) | ||||||||
L5 | Double channel relay output module (capacity 250VAC/2A) | ||||||||
G | Solid relay driving voltage output module (DC12V/30mA) | ||||||||
W1/W2 | Silicon controlled rectifier contactless switch output module (W1 for NO, W2 for NC) | ||||||||
Auxiliary port (AUX) | L0 | For domestic large size single channel relay output module (capacity 250VAC/2A) | |||||||
L1 | For domestic large size single channel relay output module (capacity 250VAC/2A) | ||||||||
L2 | For small size single channel relay output module (capacity 250VAC/1A) | ||||||||
L4 | For small size single channel relay output module (capacity 250VAC/2A) | ||||||||
L5 | Double channel relay output module (capacity 250VAC/2A) | ||||||||
G | Solid relay driving voltage output module (DC12V/30mA) | ||||||||
X3/X5 | Photoelectric isolation linear current output module (X3 use power from instrument, X5 with isolated power) | ||||||||
R | RS232 communication interface, will take 12V power port of the instrument | ||||||||
Communication (COMM) | S/S4 | Photoelectric isolation RS485 communication interface (S use power from the instrument, S4 with isolated power) | |||||||
Color | Q | Black | |||||||
Z | Gray |