Service in 24 hours

029 - 81292510

Home>GAIMC>Rotameter>GAIMC GAIMC

1.Applicable for inflammable and explosive occasion

2.Designed for measurement of small caliber and low-speed medium

3.Low requirement for the straight tube section

4.instantaneous/ cumulative flow rates displayed

  • 请填写标题
share:

GMT100

Description variable area flowmeter

Features

 

  Dual-line display, instantaneous/ cumulative flow rates displayed at the field

 

 Non-contact magnetic coupling transmission

 

 With function of data recovery, data backup and power failure protection

 

 Multiple parameters calibrating function

 

Specification variable area flowmeter

Item 

Specification

Diameter

DN15,DN25,DN50,DN80,DN100,DN150

(Please contact us for other dimension)

Range of flow

Liquid:1.0~150000l/h 

Gas:0.05~3000m3/h

Measure ratio

10:1, 20:1(special)

Accuracy

0.5, 1.0 (special)

Pressure rating

DN15,DN25,DN50: 4.0MPa(Max: 20MPa)

DN80,DN100,DN150:1.6MPa 

(DN80:Max 10MPa;DN100:Max  6.4MPa:DN150:Max 4.0MPa)

Medium temperature

Standard:-30~+120℃,high temperature:120~350

Power supply

24VDC(12~36VDC)

Output signal

4~20mADC (two-wire configuration); attached HART Protocol allowed

Output load

500Ω(24V power supply)

Operating temperature

Compact type:-40~120

Remote type:-30~60

Storage requirement

Temperature:-40~85  humidity:≤85%

Connection mode

Flange connecting. Flange standard: GB/T9119-2000; User’s appointment allowed

Cable interface

M20×1.5

Housing ingress protection

IP65

Explosion-proof

Intrinsic safety type:ExiaIICT6

explosion-proof type:ExdIICT6

Pressure loss

See table of flow for detailed information

Viscosity of medium

DN15:&eta;<5mPa.s 

DN25:&eta;<250mPa.s

DN50~DN150:&eta;<300mPa.s

Contact material

R1:304,1Cr18Ni9Ti;

Ro:316,0Cr18Ni12Mo2Ti;

RL:316L,00Cr17Ni14Mo2Ti;

Ti:Titanium alloy;

Rp:PTFE lining

 

Flow range 

 

Diameter (mm)

Float type

Flow range

Pressure loss (Kpa)

Water L/h

Air  m3/h

Water

Air

Normal

Anti-corrosion

Standard

Normal

Anti-corrosion

 

 

 

 

 

15

A

2.5~25

/

0.07~0.7

6.5

/

7.1

B

4.0~40

2.5~25

0.11~1.1

6.6

5.5

7.2

C

6.3~63

4.0~40

0.18~1.8

6.6

5.5

7.3

D

10~100

6.3~63

0.28~2.8

6.6

5.6

7.5

E

16~160

10~100

0.48~4.8

6.8

5.6

8.0

F

25~250

16~160

0.7~7.0

7.0

5.8

10.8

G

40~400

25~250

1.0~10

8.6

6.1

10.0

H

63~630

40~400

1.6~16.0

11.1

7.3

14.0

 

 

 

25

A

100~1000

63~630

3~30

7.0

5.9

7.7

B

160~1600

100~1000

4.5~45

8.0

6.0

8.8

C

250~2500

160~1600

7~70

10.8

6.8

12.0

D

400~4000

250~2500

11~110

15.8

9.2

19.0

 

40

A

500~5000

300~3000

12~120

10.8

8.6

9.8

B

600~6000

350~3500

16~160

12.6

10.4

16.5

 

 

50

A

630~6300

400~4000

18~180

8.1

6.8

8.6

B

1000~10000

630~6300

25~250

11.0

9.4

10.4

C

1600~16000

1000~10000

40~400

17.0

14.5

15.5

 

80

A

2500~25000

1600~16000

60~600

8.1

6.9

12.9

B

4000~40000

2500~25000

80~800

9.5

8.0

18.5

100

A

6300~63000

4000~40000

/

15.0

8.5

/

150

A

20000~100000

/

/

19.2

/

/

 

Detail show variable area flowmeter

 GMT100

GMT100 FLOW METER


 

Application variable area flowmeter

GMT100


Dear friend, please put your precious opinions feedback to us through the below table, we will contact you as soon as possible. (Symbol * is required)