Service in 24 hours

029 - 81292510

Home>GAMICOS>External Level Meter>GAMICOS GAMICOS

With the Frequency conversion ultrasonic technology

Non-contact, Liquid level point measurement

Safety, economical and convenient

  • 请填写标题
share:

Description


GUT603 Ultrasonic external liquid level switch adopt “Frequency conversion ultrasonic technology” to realize the detection of liquid level switch. The measuring probe adsorption in the outer wall of the container, it is a complete non-contact instruments that detect level from the outside of tank, suitable for all kinds of liquid.


▉ Safe: 

No leak source will be created during installation or maintenance, hence the product will not cause leakage or explosion during usage, even under conditions that the product is damaged or in repair.

▉ Easy installation: 

Direct installation that will not affect operation of the tank or other instruments. Installation process will not cause flame or explosion. 

▉ Reliability: with the Variable frequency ultrasonic technology, which can effectively eliminate the interference and drift.

▉ High accuracy: 1±mm 


Type

Flameproof

Ultrasonic external liquid level switch

Intrinsic safety

Ultrasonic external liquid level switch

Single point

Double point

Single point

Double point

Theory

Frequency conversion ultrasonic technology

Accuracy

±1mm±2mm±5mm

Hysteresis

1S

7S

1S

2S

Instrument Dimension

341*235*173.5MM

250*165*70MM

Instrument material

ADC12(Die-casting aluminum)

Probe dimension

Ф80*102mm

Probe shell material

PBT

Probe installation

Strong magnetic adsorption, bonding, welding

Output signal

Relay outputRS485,Modbus

4-20mA

Contact form

SPST

/

Contact capacity

5A DC30V, 5A AC220V

/

Power supply

DC24V, AC220V

DC24V

Rated power

3W

The max. 600mW

Protection class

IP67

IP65

Explosion-proof grade

EX dIICTGb

EX iaIICT6Ga

Corrosion-proof grade

WF1

Wire length from sensor to the host

≤30m

cable configuration

6'galvanized pipe,  G3/4"(M)

Fixed instrument

2"vertical pipe installation

Electrical interface of

Instrument power and output

G1/2"(F)

Electrical interface of Sensor wiring

G1/2"(F)

Electrical interfaceothers

M20*1.5, G3/4", 1/2"NPT, 3/4"NPT, G1/2"


GUT603

Ultrasonic external liquid level switch


Code

Type

I

Intrinsic safety type  

EX iaIICT6Ga

E

Flame-proof type    

EX dIICTGb

W

Waterproof type

IP67


Code

Measuring points

1

Single point

2

Double point


Code

Accuracy

A

±1mm

B

±2mm

C

±5mm


Code

Output signal

R

Relay outputnormally open, contact load 5A

Z

Relay output+RS485bus

L

Two wire system relay output module

M

Two wire system intelligent output module

Relay output+RS485bus

X

Two wire system 4-20mA


Code

Power supply

D

DC 24V (Standard)

A

AC 220V


Code

Temp. range of tank wall

B

-60~80℃

M

-60~160℃

H

-60~220℃

L

Customized at the low temp.

O

Customized at the high temp.


Dear friend, please put your precious opinions feedback to us through the below table, we will contact you as soon as possible. (Symbol * is required)